Code: C3200
Description: Exposure lamp problem
When input value at the time of exposure lamp illumination does not exceed the threshold value between 5 s.
When input value at the time of exposure lamp illumination does not exceed the threshold value between 5 s.
Causes: Poor contact in the connector terminals.
Defective exposure lamp or inverter PWB.
Incorrect shading position.
Defective PWB
Defective exposure lamp or inverter PWB.
Incorrect shading position.
Defective PWB
Remedy: Poor contact in the connector terminals. Check the connection of connector YC5 on the ISM PWB and the connector on the inverter PWB, and the continuity across the connector terminals. Repair or replace if necessary.
Defective exposure lamp or inverter PWB. Replace the exposure lamp or inverter PWB.
Incorrect shading position. Adjust the position of the contact glass (shading plate). If the problem still occurs, replace the scanner home position switch.
Defective PWB. Replace the ISM PWB, ISC PWB or CCD PWB and check for correct operation.
Defective exposure lamp or inverter PWB. Replace the exposure lamp or inverter PWB.
Incorrect shading position. Adjust the position of the contact glass (shading plate). If the problem still occurs, replace the scanner home position switch.
Defective PWB. Replace the ISM PWB, ISC PWB or CCD PWB and check for correct operation.