Code: 8140
Description: DF tray error 1 In case unable to detect the DF tray sensor 1 or DF tray upper level sensor is turned ON when the main tray ascends and 30 s have passed.
Remedy: DF tray motor 1. Execute [Motor] > [Tray] in U240 Checking the operation of the finisher. 2. Check if the main tray can be moved up and down manually without getting caught. 3. Check if the motor drive is delivered to the main tray. 4. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. DF tray motor - DF main PWB(YC12) 5. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 6. Replace the DF tray motor.
DF tray sensor 1 DF tray upper surface sensor 1. Execute [Finisher]>[Tray U-Limit, Tray Top] in U241 Checking the operation of the finisher switch. 2. Check if there is a failure in the position of the sensor or mounting plate. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. DF tray sensor 1 - DF main PWB(YC19) DF tray upper surface sensor - DF main PWB(YC15) 4. Replace the DF tray sensor 1 or DF tray upper surface sensor.
DF main PWB Replace the DF main PWB.
DF tray sensor 1 DF tray upper surface sensor 1. Execute [Finisher]>[Tray U-Limit, Tray Top] in U241 Checking the operation of the finisher switch. 2. Check if there is a failure in the position of the sensor or mounting plate. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. DF tray sensor 1 - DF main PWB(YC19) DF tray upper surface sensor - DF main PWB(YC15) 4. Replace the DF tray sensor 1 or DF tray upper surface sensor.
DF main PWB Replace the DF main PWB.