Code: 3100
Description: Scanner carriage error
The home position is not correct when the power is turned on, at the end of a reading process of the table and document processor.
The home position is not correct when the power is turned on, at the end of a reading process of the table and document processor.
Causes: The scanner mirror frame is being locked after setup. Scanner motor. Home position sensor. ISC PWB. Main PWB.
Remedy: The scanner mirror frame is being locked after setup. Check whether the scanner mirror frame has been unlocked and unlock if necessary.
Scanner motor 1. To check the scanner motor, execute U073. 2. Move the scanner by the hand to check whether it is unusually difficult to move. 3. Check that the optical wire rope is not disengaged and engage the wire. 4. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Scanner motor and ISC PWB (YC5) ISC PWB (YC3) and Main PWB (YC11) 5. If the wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the scanner motor.
Home position sensor 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Home position sensor and ISC PWB (YC8) 3. Replace the home position sensor.
ISC PWB Replace the ISC PWB and execute U411.
Main PWB Replace the main PWB.
Scanner motor 1. To check the scanner motor, execute U073. 2. Move the scanner by the hand to check whether it is unusually difficult to move. 3. Check that the optical wire rope is not disengaged and engage the wire. 4. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Scanner motor and ISC PWB (YC5) ISC PWB (YC3) and Main PWB (YC11) 5. If the wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the scanner motor.
Home position sensor 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Home position sensor and ISC PWB (YC8) 3. Replace the home position sensor.
ISC PWB Replace the ISC PWB and execute U411.
Main PWB Replace the main PWB.