Code: 8320
Description: CF adjustment motor error (4000-sheet finisher)
When initial operation, CF adjustment sensor does not turn on within 2.5 s.
When initial operation, CF adjustment sensor does not turn on within 2.5 s.
Causes: CF adjustment motor1,2. CF adjustment sensor1,2. CF main PWB.
Remedy: CF adjustment motor1,2 1. Execute U240 Booklet - Bundle Up / Down to check the finisher operation. 2. Manipulate the fold moving belt up and down to check it is smoothly operable. 3. Check that the drive from the motor reaches the fold moving belt. (Check if the belt is bent.) 4. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. CF adjustment motor 1,2 and CF main PWB (YC10) 5. If the wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the CF adjustment motor1,2.
CF adjustment sensor1,2 1. Execute U241 Booklet - bundle Up / Down HP to check the finisher switch. 2. Check that the sensor and its mounting bracket are correctly positioned. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. CF adjustment sensor 1,2 and CF main PWB (YC20) 4. Replace the CF adjustment sensor1,2.
CF main PWB Replace the CF main PWB.
CF adjustment sensor1,2 1. Execute U241 Booklet - bundle Up / Down HP to check the finisher switch. 2. Check that the sensor and its mounting bracket are correctly positioned. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. CF adjustment sensor 1,2 and CF main PWB (YC20) 4. Replace the CF adjustment sensor1,2.
CF main PWB Replace the CF main PWB.