Code: E-001
Description: Fuser Over Temperature Error
Fuser Temperature reaches over 230C.
Fuser Temperature reaches over 230C.
Remedy: Error clearance 1 Have you cleared the fuser error in the Error Clear Mode? (Refer to the page 8-154 as for the Error Clear Mode.) Yes Wait until the Fuser Unit is enough cooled down. Then select the Error Clear Mode and clear the concerning error. Wires 2 Are wires among Lamp (H1, H2), Solid State Relay (SSR1) and Thermistors (TH1 & TH2) connected properly? No Connect them properly. Solid State Relay (SSR1) 3 Does the error occur again even if you have cleared it in the Error Clear Mode? Yes Replace the Solid State Relay. Thermistors (TH1 & TH2) 4 Select the Information Mode, and then check the temperature of fuser detected by Thermistors (TH1 & TH2). Item No. : 00 (Fuser temperature 1) 01 (Fuser temperature 2) Is each temperature normal? No Replace the concerning Thermistor.