Code: E-011
Description: Fuser Motor Error
The Fuser Motor Output Detection Signal (HEATM_LD) continues to be “H” for 3 seconds or longer when the Fuser Motor is rotating.
The Fuser Motor Output Detection Signal (HEATM_LD) continues to be “H” for 3 seconds or longer when the Fuser Motor is rotating.
Remedy: Wires 1 Is the wire between Fuser Motor and PW12420 PCB connected properly? No Connect it properly. Confirm that the machine is turned on, and then check the voltage of the orange line (J220-4). Is it 24V? No Replace the DC Power Supply if there is no problem with the wires. DC Power Supply (DCP1) or Fuse 2 Confirm that the machine is turned off, and then check whether or not each Fuse is broken. Is any Fuse broken? Yes Replace the Fuse. Fuser Motor (M2) 3 Check the operation of Fuser Motor in the Device Operation Mode of the Service Mode. Device Code : 01 (Fuser Motor) Does the Fuser Motor operate correctly? No Replace the Fuser Motor.