Code: E-012
Description: Developer Press Motor Error
The Developer Press Sensor Signal (PRESS_S) does not change to “L” within 30 seconds after turning on.
The Developer Press Sensor Signal (PRESS_S) does not change to “L” within 30 seconds after turning on.
Remedy: Wires 1 Are the wires among Developer Press Sensor (PH4), PW12420 PCB, Driver PCB B (PW6654) and Developer Press Motor (M4) connected properly? No Connect them properly. Developer Press Motor (M4) Driver PCB B (PW6654) 2 Turn off the machine, and then turn it on again. Is the Developer Unit moved to the Drum side? No Replace the Developer Press Motor or Driver PCB B. Developer Press Sensor (PH4) 3 Select the Signal Code “104” (Developer Press Sensor) in the Signal Status Mode, and then turn on the machine again. Does the status change from “H” to “L” after turning on? No Replace the Developer Press Sensor. Fuse 4 Does the fuse (F3) have a proper conductivity? No Replace the fuse (F3).