Code: E-020
Description: Counter Error
The Counter Connection Detection Signal (COUNT_OPN) continues to be “L” for 1 second or longer after turning on.
The Counter Connection Detection Signal (COUNT_OPN) continues to be “L” for 1 second or longer after turning on.
Remedy: Wires 1 Is the wire between Counter and PW12420 PCB connected properly? No Connect it properly. Confirm that the machine is turned on, and then check the voltage of the orange line (J220-5). Is it 24V? No Replace the DC Power Supply if there is no problem with the wires. DC Power Supply (DCP1) or Fuse 2 Turn off the machine. Does the fuse (F1) have a proper conductivity? No Replace the fuse (F1). Counter 3 Check the operation of Counter in the Device Operation Mode of the Service Mode. Device Code : 26 (Counter) Does the Counter operate correctly? No Replace the Counter.