Mã lỗi C8120 — Kyocera TASKalfa 5002i

Code: C8120

Description: DF shift motor 2 error Object: 4000-sheet finisher
Causes: DF shift sensor 2 does not turn on even if shifting 160mm when driving DF shift motor 2.
Remedy: 1 Checking the rear shift guide The rear shift guide is not assembled properly. If the rear shift guide is not shifted manually, repair the part that restricts the operation. 2 Checking the rear shift guide drive components The rear shift guide drive components are not properly attached, or they are faulty. Reattach the rear shift guide drive components. Then, replace them if they are not fixed 3 Checking the wire The wire is not properly connected or is faulty. Reinsert the following wire connectors, and replace the wires if there is no continuity.• DF shift motor 2 - DF main PWB• DF shift sensor 2 - DF main PWB Electrical Diagram of PWBs 4 Checking DF shift motor 2 DF shift motor 2 is faulty. Replace DF shift motor 2 if it does not operate properly when checking the operation at U240. U240 Execution 5 Checking DF shift sensor 2 DF shift sensor 2 is not properly attached, or it is faulty. Reattach DF shift sensor 2. Then, execute U241 to check the operation. If it does not properly operate, replace the sensor. U241 Execution 6 Replacing the DF main PWB The DF main PWB is faulty. Replace the DF main PWB. DF Main PWB Replacement