Code: C1020
Description: Lift motor 2 error
After cassette 2 is inserted, lift limit switch 2 does not turn on within 12 s. This error is detected four times successively.
After cassette 2 is inserted, lift limit switch 2 does not turn on within 12 s. This error is detected four times successively.
Causes: Poor contact in the connector terminals.
Broken gears or couplings of lift motor 2.
Defective lift motor 2.
Defective lift switch 2.
Poor contact in the connector terminals.
Defective PWB
Broken gears or couplings of lift motor 2.
Defective lift motor 2.
Defective lift switch 2.
Poor contact in the connector terminals.
Defective PWB
Remedy: Poor contact in the connector terminals. Check the connection of connector of lift motor 2 and the connector YC3 on the feed PWB, and the continuity across the connector terminals. Repair or replace if necessary.
Broken gears or couplings of lift motor 2. Replace lift motor 2.
Defective lift motor 2. Check for continuity across the coil. If none, replace lift motor 2.
Defective lift switch 2. Check if YC4-8 on the feed PWB goes low when lift switch 2 is turned off. If not, replace lift switch 2.
Poor contact in the connector terminals. Check the connection of connector of lift switch 2 and the connector YC4 on the feed PWB, and the continuity across the connector terminals. Repair or replace if necessary.
Defective PWB. Replace the feed PWB or engine PWB and check for correct operation.
Broken gears or couplings of lift motor 2. Replace lift motor 2.
Defective lift motor 2. Check for continuity across the coil. If none, replace lift motor 2.
Defective lift switch 2. Check if YC4-8 on the feed PWB goes low when lift switch 2 is turned off. If not, replace lift switch 2.
Poor contact in the connector terminals. Check the connection of connector of lift switch 2 and the connector YC4 on the feed PWB, and the continuity across the connector terminals. Repair or replace if necessary.
Defective PWB. Replace the feed PWB or engine PWB and check for correct operation.