Code: C6200
Description: Fuser heater 1 edge break
During warming up, fuser thermistor 1 does not detect temperature rise of 1C/ 1.8F for 10 s. Fuser thermistor 1 does not reach 90F even after 30 s during warming up.
During warming up, fuser thermistor 1 does not detect temperature rise of 1C/ 1.8F for 10 s. Fuser thermistor 1 does not reach 90F even after 30 s during warming up.
Causes: Defective fuser heater 1.
Defective fuser thermostat 1.
Installation defectiveness on fuser thermistor 1.
Defective PWB.
Defective fuser thermostat 1.
Installation defectiveness on fuser thermistor 1.
Defective PWB.
Remedy: Defective fuser heater 1. Check for continuity across each heater. If none, replace the fuser unit.
Defective fuser thermostat 1. Check for continuity across thermostat. If none, remove the cause and replace the fuser unit.
Installation defectiveness on fuser thermistor 1. Measure the resistance. If it is ∞, replace the fuser unit.
Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.
Defective fuser thermostat 1. Check for continuity across thermostat. If none, remove the cause and replace the fuser unit.
Installation defectiveness on fuser thermistor 1. Measure the resistance. If it is ∞, replace the fuser unit.
Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.