Code: C8090

Description: DF paddle motor error
Causes: 1. The DF paddle sensor does not turn on after passing 1s when driving the DF paddle motor.2. The DF paddle sensor does not turn off when driving the DF paddle motor for 1s.
Remedy: 1 Checking the DF paddle drive components The DF paddle drive components are not properly attached, or it is faulty. Reattach the DF paddle drive components. Then, replace them if they are not fixed. 2 Checking the wire The wire is not properly connected or is faulty. Reinsert the following wire connectors, and replace the wires when they have no continuity.• DF paddle motor - DF main PWB• DF paddle sensor - DF main PWB Electrical Diagram of PWBs 3 Replacing the DF paddle motor The DF paddle motor is faulty. Replace the DF paddle motor if it does not operate properly when checking the operation at U240. U240 Execution 4 Replacing the DF paddle sensor The DF paddle sensor is faulty. Replace the DF paddle sensor if it does not operate properly when checking the operation at U241. U241 Execution 5 Replacing the DF main PWB The DF main PWB is faulty. Replace the DF main PWB. DF Main PWB Replacement