Mã lỗi C8330 — Kyocera TASKalfa 5052ci

Code: C8330

Description: BF blade motor error Object: 4000-sheet finisher with the folding unit
Causes: The BF blade sensor does not turn on after passing 3s during the initial operation.
Remedy: 1 Checking the BF blade The BF blade is not assembled properly. If the BF blade is not operated manually, repair the part that restricts the operation. 2 Checking the BF blade drive components The BF blade drive components are not properly attached, or they are faulty. Reattach the BF blade drive components.Then, replace them if they are not fixed. 3 Checking the wire The wire is not properly connected or is faulty. Reinsert the following wire connectors, and replace the wires there is no continuity.• BF blade motor - BF main PWB• BF blade sensor - BF main PWB Electrical Diagram of PWBs 4 Replacing the BF blade motor The BF blade motor is faulty. Replace the BF blade motor if it does not operate properly when checking the operation at U240. U240 Execution 5 Checking the BF blade sensor The BF blade sensor is not properly attached. Reattach the BF blade sensor and execute U241 to check the operation.Then, replace the BF blade sensor if it does not operate properly. U241 Execution 6 Replacing the BF main PWB The BF main PWB is faulty. Replace the BF main PWB.