Description: BF staple motor error 1 Object: 4000-sheet finisher with the folding unit
Causes: The BF staple jam was detected 2 times continuously.(Detection condition of 2nd paper jam: The home position cannot be detected after passing 600ms since starting up the motor.)
Remedy: 1 Checking the BF staple unit The BF staple unit is not assembled properly. If the BF staple unit is not operated manually, repair the part that restricts the operation. 2 Checking the BF staple unit drive components The BF staple unit drive components are not properly attached, or they are faulty. Reattach the BF staple unit drive components. Then, replace them if they are not fixed. 3 Checking the wire The wire is not properly connected or is faulty. Reinsert the following wire connectors, and replace the wire when it has no continuity.• BF staple unit - BF main PWB Electrical Diagram of PWBs 4 Replacing the BF staple motor The BF staple motor is faulty. Replace the BF staple motor if it does not operate properly when checking the operation at U240. U240 Execution 5 Replacing the BF staple unit The BF staple unit is faulty. Replace the BF staple unit. 6 Replacing the BF main PWB The BF main PWB is faulty. Replace the BF main PWB.