Code: 8100
Description: DF eject release motor error
When the DF eject release motor is driven, DF bundle discharge sensor does not turn on within 1 s.
When the DF eject release motor is driven, DF bundle discharge sensor does not turn on within 1 s.
Causes: DF eject release motor DF bundle discharge unit sensor. DF bundle discharge unit sensor. DF main PWB.
Remedy: DF eject release motor DF bundle discharge unit sensor 1. Execute U240 Motor - Eject Unlock (Full) to check the finisher operation. 2. Check that the eject guide of the process tray is opened and, if not, correct the guide. 3. Check that the drive from the motor reaches the eject guide. 4. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF bundle discharge unit sensor and DF main PWB (YC22)(4000-sheet finisher) DF bundle discharge unit sensor and DF main PWB (YC20)(1000-sheet finisher) 5. If the wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the DF eject release motor.
DF bundle discharge unit sensor 1. Execute U241 Finisher - Bundle Eject HP to check the finisher switch. 2. Check that the sensor and its mounting bracket are correctly positioned. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF bundle discharge unit sensor and DF main PWB (YC22)(4000-sheet finisher) DF bundle discharge unit sensor and DF main PWB (YC20)(1000-sheet finisher) 4. Replace the DF bundle eject unit sensor.
DF main PWB Replace the DF main PWB (Refer to the service manual for the document finisher).
DF bundle discharge unit sensor 1. Execute U241 Finisher - Bundle Eject HP to check the finisher switch. 2. Check that the sensor and its mounting bracket are correctly positioned. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF bundle discharge unit sensor and DF main PWB (YC22)(4000-sheet finisher) DF bundle discharge unit sensor and DF main PWB (YC20)(1000-sheet finisher) 4. Replace the DF bundle eject unit sensor.
DF main PWB Replace the DF main PWB (Refer to the service manual for the document finisher).