Mã lỗi C473 — Kyocera TASKalfa 550c

Code: C473

Description: Surge pressure detection / power and voltage upper limit abnormality
Remedy: 1. Check the power voltage (1) Check if the power voltage is normal.(Is the voltage during the operation ?10% of the rated voltage?) 2. Check the thermostat (1) Check if the thermostat is blown. 3. Check the IH board (1) Check if the connectors of the power supply unit are disconnected (power supply unit AC output connector and LGC I/F connector CN404). (2) Check if the fuse on the IH board has blown. (3) Replace the IH board. 4. Check the LGC board (1) Check if the connectors CN305/CN306 are disconnected. (2) Check if the conductor pattern on the board is short circuited or open circuited. (3) Replace the LGC board. 5. Clear the status counter Change the current status counter value "1" or "2" to "0", then press [ENTER] or [INTERRUPT].