Description: High-voltage transformer abnormality: Leakage of the main charger is detected.
Remedy: (1) Is the main charger installed securely? (2) Check if the spring of high-voltage supply contact point is deformed. (3) Check if the needle electrode is broken or the main charger grid is deformed. (4) Check if any foreign matter is on the needle electrode or main charger grid. (5) Check if any foreign matter is adhering on the high-voltage terminal of the EPU tray. (6) Check if there is a sign of discharge on the joint of the high-voltage terminal of the EPU tray and the main charger. Correct if there is.