Code: CD71
Description: Waste toner transport motor locking error: The auger in the waste toner transport path does not rotate.
Remedy: (1) Pull out the process unit, rotate the gear counterclockwise and check if the load is extremely heavy. (2) Is the load still extremely heavy after the gear is rotated for a while to discharge the toner from the waste toner transport path? (3) Is the load still extremely heavy after the actuator is removed, the auger is pulled out and clean them? (4) Check if there is any abnormality of the mechanism in the waste toner transport path. (5) Does the waste toner transport motor (M31) rotate? (Output check: 03-234) (6) Are the connector of the waste toner transport motor and the relay connector disconnected? (7) Is the driving gear of the waste toner transport motor damaged or abnormal? (8) Is the connector (CN331) on the LGC board disconnected? (9) Check if the connector pins are disconnected or the harnesses are open-circuited. (10) Check if the conductor pattern on the LGC board is short circuited or open circuited. (11) Replace the waste toner transport motor. (12) Replace the LGC board. (13) Are the auger lock detection sensor (S42) working? (Input check: 03-[FAX]ON/[0]/[B]) (14) Check if each Normal/Highlighted display is reflected correctly to judge the malfunction. (15) Is the connector of the auger lock sensor disconnected? (16) Is the connector (CN557) on the EPU board disconnected? (17) Check if the connector pins are disconnected, the EPU drawer connector pins are disconnected or bent or the harnesses are open-circuited. (18) Check if the conductor pattern on the EPU board is short circuited or open circuited. (19) Replace the auger lock detection sensor. (20) Replace the EPU board. (21) Check if there is any abnormality of the mechanism such as the sensor's actuator.