Code: C1130
Description: PF right lift position problem (optional 3000-sheet paper feeder)
Level switch 2 does not turn on within 30 s of PF lift motor 1 turning on.
Level switch 2 does not turn on within 30 s of PF lift motor 1 turning on.
Causes: Poor contact in the connector terminals.
Defective level switch 2.
Defective PF lift motor 1.
The PF right lift does not rise properly.
Defective level switch 2.
Defective PF lift motor 1.
The PF right lift does not rise properly.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC27 on the engine PWB and the connector on the PF main PWB, and the continuity across the connector terminals. Repair or replace if necessary.
Defective level switch 2. Check if YC5-7 on the PF main PWB goes low when level switch 2 is turned off. If not, replace PF lift switch 2.
Defective PF lift motor 2. Check for continuity across the coil. If none, replace PF lift motor 2.
The PF right lift does not rise properly. Check the gears and belts, and remedy if necessary.
Defective level switch 2. Check if YC5-7 on the PF main PWB goes low when level switch 2 is turned off. If not, replace PF lift switch 2.
Defective PF lift motor 2. Check for continuity across the coil. If none, replace PF lift motor 2.
The PF right lift does not rise properly. Check the gears and belts, and remedy if necessary.