Code: C9010
Description: Coin vender communication error
A communication error from coin vender is detected 10 times in succession.
A communication error from coin vender is detected 10 times in succession.
Causes: Poor contact in the connector terminals.
Data setting failure.
Defective coin vender control PWB.
Defective main PWB.
Data setting failure.
Defective coin vender control PWB.
Defective main PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector on the main PWB and the connector on the coin vender control PWB, and the continuity across the connector terminals. Repair or replace if necessary.
Data setting failure. Set maintenance mode U206 to off when a coin vender is not installed.
Defective coin vender control PWB. Replace the coin vender control PWB.
Defective main PWB. Replace the main PWB and check for correct operation.
Data setting failure. Set maintenance mode U206 to off when a coin vender is not installed.
Defective coin vender control PWB. Replace the coin vender control PWB.
Defective main PWB. Replace the main PWB and check for correct operation.