Description: DP lift motor ascend error Object: Dual scan DP and automatic duplex DP with the DP feed belt
Causes: Turning on of the DP lift upper limit sensor could not be detected after passing 3000 pulses during the DP lift motor ascend drive. That status was continued 5 times or more.
Remedy: 1 Checking the original lift plate The DP original lift plate is not properly attached. If the original lift plate is not shifted manually vertically, repair the part that restricts the operation. 2 Checking the wire The wire is not properly connected or is faulty. Reinsert the following wire connectors, and replace the wires when they have no continuity.• DP lift motor - DP main PWB• DP lift upper limit sensor - DP main PWB Electrical Diagram of PWBs 3 Replacing the DP lift motor The DP lift motor is faulty. Replace the DP lift motor if it does not operate properly when checking the operation at U243. U243 Execution 4 Checking the DP lift upper limit sensor The DP lift upper limit sensor is not properly attached, or it is faulty. Reattach the DP lift upper limit sensor and execute U241 to check the operation. If it does not operate properly, replace the sensor. U244 Execution 5 Replacing the DP main PWB The DP main PWB is faulty. Replace the DP main PWB. DP Main PWB Replacement