Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C8410 — Kyocera TASKalfa 6052ci

Code: C8410

Description: PH slide motor error 1 Object: 4000-sheet finisher or 1000-sheet finisher with the punch unit
Causes: The PH slide sensor does not turn on after shifting 30mm when relocating to the home position.
Remedy: 1 Checking the punch unit The punch unit is not assembled properly. If the punch slide section is not shifted manually forwardbackward, repair the part that restricts the operation. 2 Checking the punch drive components The punch drive components are not properly attached, or they are faulty. Reattach the punch drive components. Then, replace them if they are not fixed. 3 Checking the wire The wire is not properly connected or is faulty. Reinsert the following wire connectors, and replace the wires when they have no continuity.• PH slide motor - PH main PWB• PH slide sensor - PH main PWB• PH main PWB - DF main PWB Electrical Diagram of PWBs 4 Replacing the PH slide motor The PH slide motor is faulty. Replace the PH slide motor if it does not operate properly when checking the operation at U240. U240 Execution 5 Checking the PH slide sensor The PH slide sensor is not properly attached, or it is faulty. Reattach the PH slide sensor and execute U241 to check the operation. If it does not properly operate, replace the sensor. U241 Execution 6 Replacing the PH main PWB The PH main PWB is faulty. Replace the PH main PWB. 7 Replacing the DF main PWB The DF main PWB is faulty. Replace the DF main PWB. DF Main PWB Replacement

← Xem tất cả mã lỗi Kyocera TASKalfa 6052ci

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie