Code: C3210
Description: CIS lamp problem
• After the reading starting, when input value at the time of CIS illumination does not exceed the threshold value between 5 s.
• After the reading starting, when input value at the time of CIS illumination does not exceed the threshold value between 5 s.
Causes: Defective DP main PWB.
Poor contact in the connector terminals.
Defective CIS.
Defective DP inverter PWB.
Poor contact in the connector terminals.
Defective CIS.
Defective DP inverter PWB.
Remedy: Defective DP main PWB. Replace the DP main PWB and check for correct operation.
Poor contact in the connector terminals. Check the connection of connector YC2 on the DP main PWB and the continuity across the connector terminals. Repair or replace if necessary.
Defective CIS. Replace CIS and check for correct operation.
Defective DP inverter PWB. Replace the DP inverter PWB and check for correct operation.
Poor contact in the connector terminals. Check the connection of connector YC2 on the DP main PWB and the continuity across the connector terminals. Repair or replace if necessary.
Defective CIS. Replace CIS and check for correct operation.
Defective DP inverter PWB. Replace the DP inverter PWB and check for correct operation.