Code: C8140
Description: Document finisher main tray problem
• When the main tray is not detected by the main tray upper limit detection sensor or the main tray load detection sensor within 20 s from the moment it starts ascending.
• During main tray descent, the main tray upper limit detection sensor or the main tray load detection sensor does not turn off within 500 ms after it turns on.
• During main tray ascent, the main tray upper limit detection sensor or the main tray load detection sensor stays on for more than 2 s.
• When the main tray is not detected by the main tray upper limit detection sensor or the main tray load detection sensor within 20 s from the moment it starts ascending.
• During main tray descent, the main tray upper limit detection sensor or the main tray load detection sensor does not turn off within 500 ms after it turns on.
• During main tray ascent, the main tray upper limit detection sensor or the main tray load detection sensor stays on for more than 2 s.
Causes: Loose connection of the main tray elevation motor connector.
Malfunction of the main tray elevation motor.
Malfunction of the main tray upper limit detection sensor.
Loose connection of the main tray upper limit detection sensor connector.
Malfunction of the main tray load detection sensor.
Loose connection of the main tray load detection sensor connector.
Defective finisher main PWB.
Malfunction of the main tray elevation motor.
Malfunction of the main tray upper limit detection sensor.
Loose connection of the main tray upper limit detection sensor connector.
Malfunction of the main tray load detection sensor.
Loose connection of the main tray load detection sensor connector.
Defective finisher main PWB.
Remedy: Loose connection of the main tray elevation motor connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.
Malfunction of the main tray elevation motor. Replace the main tray elevation motor and check for correct operation.
Malfunction of the main tray upper limit detection sensor. Replace the main tray upper limit detection sensor and check for correct operation.
Loose connection of the main tray upper limit detection sensor connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.
Malfunction of the main tray load detection sensor. Replace the main tray load detection sensor and check for correct operation.
Loose connection of the main tray load detection sensor connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.
Defective finisher main PWB. Replace the finisher main PWB and check for correct operation.
Malfunction of the main tray elevation motor. Replace the main tray elevation motor and check for correct operation.
Malfunction of the main tray upper limit detection sensor. Replace the main tray upper limit detection sensor and check for correct operation.
Loose connection of the main tray upper limit detection sensor connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.
Malfunction of the main tray load detection sensor. Replace the main tray load detection sensor and check for correct operation.
Loose connection of the main tray load detection sensor connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.
Defective finisher main PWB. Replace the finisher main PWB and check for correct operation.