Description: Developer shutter error Power is turned on while the developer shutter is locked.
Remedy: The developer shutter has been locked. Release the developer shutter. Developer shutter sensor 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Developer shutter sensor and Front PWB (YC4) Front PWB (YC3) and Engine PWB (YC7) 2. If the wiring is disconnected, shorted or grounded, replace the wiring.