Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 8350 — Kyocera TASKalfa 6501i

Code: 8350

Description: CF side registration motor 1 error When initial operation, CF side registration sensor 1 does not turn on within 1 s.
Remedy: CF side registration motor 1 1. Execute U240 Booklet - Width Test to check the finisher operation. 2. Manipulate the side registration lower guide back and forth to check it can smoothly operable. 3. Check that the drive from the motor reaches the side registration lower guide. 4. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. CF side registration motor 1 and CF main PWB (YC10) 5. If the wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the CF side registration motor 1.
CF side registration sensor 1 1. Execute U241 Booklet - Width Down HP to check the finisher switch. 2. Check that the sensor and its mounting bracket are correctly positioned. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. CF side registration sensor 1 and CF main PWB (YC20) 4. Replace the CF side registration sensor 1.
CF main PWB Replace the CF main PWB