Description: Communication error between Main PWB and Print engine
Remedy: Main PWB 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Repair or replace the wire from the engine PWB, that may be grounded. (Check short-circuit between 5V and 3.3V.) 3. Check that the FFC wire connecting between the Main PWB (YC3) and the engine PWB (YC46) is normal and, if necessary, re-insert.Or, replace the FFC wire. 4. If not corrected, replace the main PWB. Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB. HDD Replace the HDD.