Mã lỗi C130 — Kyocera TASKalfa 650c

Code: C130

Description: 1st drawer tray abnormality: The tray-up motor is not rotating or the 1st drawer tray is not moving normally. (the case that paper can be fed from any drawer except the 1st drawer)
Remedy: Does the tray go up? (Perform the output check: 03-246, 247) NO 1. Check if the connector of the tray-up motor is disconnected. 2. Check if the connector CN508 on the PFC board is disconnected. 3. Check if the connector pins are disconnected or the harnesses are open circuited. 4. Check if the conductor pattern on the PFC board is short circuited or open circuited. 5. Replace the tray-up motor. 6. Replace the PFC board. YES Is the tray-up sensor working? (Perform the input check: 03-[Copy ON]/[9]/[H], /[9]/[G]) NO 1. Check if the connector of the sensor is disconnected. 2. Check if the connector CN513 on the PFC board is disconnected. 3. Check if the slit reaches the sensor. 4. Check if the connector pins are disconnected or the harnesses are open circuited. 5. Check if the conductor pattern on the PFC board is short circuited or open circuited. 6. Replace the tray-up sensor. 7. Replace the PFC board. YES 1. Check if the conductor pattern on the PFC board is short circuited or open circuited. 2. Replace the PFC board.