Mã lỗi C360 — Kyocera TASKalfa 650c

Code: C360

Description: Needle electrode cleaner operation abnormality
Remedy: (1) Check if there is any abnormality on the connector between the equipment and the EPU tray of the process unit. (05-2788) (2) Perform the code 08-4606- 0 to -3 (-0: K, -1: Y, -2: M, -3: C) to check which station the error is found. (3) Check if the needle electrode cleaner detection sensors (S30 - S33) are coming off of the plate of the EPU tray. (4) Are the needle electrode cleaner detection sensors (S30 - S33) working normally? (Input check: K: 03-[Fax ON]/[0]/[E], C: 03-[Fax ON]/[0]/[H], M: 03-[Fax ON]/[9]/[C], Y: 03-[Fax ON]/[9]/[F]) * If it is working properly, proceed to 11. If not, check 5 to 10 below. (5) Check if connectors of needle electrode cleaner detection sensors (S30 - S33) disconnected. (6) Check if the connectors for the needle electrode cleaner detection sensors (S30 - S33) on the EPU board (CN553 to CN556) are disconnected. (7) Check if the connector pins are disconnected or the harnesses are open circuited. (8) Check if the conductor pattern on the EPU board is open circuited or short circuited. (9) Replace the needle electrode cleaner detection sensors (S30 - S33). (10) Replace the EPU board (11) Is the needle electrode cleaner drive motors (M23 - M26) working normally? (Input check: K: 03-207, C: 03-206, M: 03-205, Y: 03-204) * If it is working properly, proceed to 22. If not, check 12 to 21 below. (12) Check if the needle electrode cleaner drive section rotates smoothly, and if it does not, clean or replace it. (13) Check if the connectors of the needle electrode cleaner drive motors (M23 - M26) and relay harnesses are disconnected. (14) Check if the relay harness and the harness relay connector on the EPU board side are disconnected (15) Check if the connectors on the EPU board (CN553 - CN556) are disconnected. (16) Check if the connector pins are disconnected or the harnesses are open circuited. (17) Check if the conductor pattern on the EPU board is open circuited or short circuited. (18) Replace the Replace the needle electrode cleaner drive motors (M23 - M26). (19) Replace the EPU board (20) Check if the harness between the EPU board (CN550) and the LGC board (CN310) is open circuited. (21) Replace the LGC board. (22) Correct the needle electrode cleaner drive section (timing belt or gears).

← Xem tất cả mã lỗi Kyocera TASKalfa 650c

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie