Remedy: (1) Check if there is any abnormality on the connector between the equipment and the EPU tray of the process unit. (05-2788) (2) Check if the sub-hopper toner motor is rotating. (Input check: 03-[FAX]OFF/[4]/[D/E/F/G]) (3) Is the sub-hopper toner supply motor locked? (Is there any foreign matter or toner-clump in the sub-hopper? (4) Check if the connector of the sub-hopper toner motor is disconnected. (5) Check if the connectors on the EPU board (CN553, 554, 555, and 556) are disconnected, or the harness is open circuited or short circuited. (6) Replace the sub-hopper toner motor. (7) Replace the EPU board. (8) Replace the LGC board.