Description: 2nd transfer roller position detection abnormality: The 2nd transfer roller does not contact/release normally.
Remedy: 519) NO 1. Check if the connector of the 2nd transfer motor is disconnected. 2. Check if the connector CN314 on the LGC board is disconnected. 3. Check if the connector pins are disconnected or the wires of harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the 2nd transfer motor. 6. Replace the LGC board. YES Is the 2nd transfer roller position detection sensor(S50) working properly? (Perform the input check:03-[All OFF]/[9]/[H]) NO 1. Check if the connector or joint connectors of the 2nd transfer roller position detection sensor are disconnected. 2. Check if the connector CN307 on the LGC board is disconnected. 3. Check if the connector pins are disconnected or the wires of harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the 2nd transfer roller position detection sensor. 6. Replace the LGC board. YES 1. Check if there is any abnormality with the mechanical section (sensor's actuator, etc.). 2. Check if the conductor pattern on the LGC board is short circuited or open circuited. 3. Replace the LGC board.