Code: E510
Description: Jam not reaching the ADU entrance sensor: The paper does not reach the ADU entrance sensor after it is switchbacked in the exit section.
Remedy: 1. Open the ADU and check if there is any paper in front of the ADU entrance sensor. * If the error still occurs, check the following. 2. Is the ADU entrance sensor working? (Perform the input check: 03-[FAX]ON/[4]/[B]) * If it is working properly, proceed to 7. If not, check 3 to 6 below. 3. Check if the connectors CN511 on the PFC board is disconnected from the ADU entrance sensor or the harnesses are open circuited. Check if the connectors CN491 and CN492 on the ADU board are disconnected. Correct if any. 4. Replace the ADU entrance sensor. 5. Replace the ADU board. 6. Replace the PFC board. 7. Is the reverse motor working? (Perform the output check: 03-132/134) * If it is working properly, proceed to 11. If not, check 8 to 10 below. 8. Check if the connector CN515 on the PFC board is disconnected from the reverse motor or the harnesses are open circuited. Correct if any. 9. Replace the reverse motor. 10.Replace the PFC board. 11.Is the ADU motor working? (Perform the output check: 03-144) * If it is working properly, proceed to 16. If not, check 12 to 15 below. 12.Check if the connectors CN511 on the PFC board is disconnected from the ADU motor or the harnesses are open circuited. Check if the connectors CN495 and CN491 on the ADU board are disconnected. Correct if any. 13.Replace the ADU motor. 14.Replace the ADU board. 15.Replace the PFC board. 16.Check the rollers in the ADU, the exit roller and the pressure spring of the equipment. Replace them if they are worn out.