Description: Intermediate transfer belt meandering correction error If the intermediate transfer belt position detecting sensor has derived an incorrect value.
Remedy: Intermediate transfer belt unit 1. Check that the Intermediate transfer belt unit has been properly installed so that the intermediate belt unit waste toner shutter won’t be derailed when the belt unit is strongly inserted. 2. Reinstall the intermediate transfer belt unit (Insert slowly all the way in). 3. Run U469 Belt Position with B/W and confirm “angle” (position of belt) is within the range (6 to 26). 4. Check that the main unit is placed perfectly horizontal. 5. Replace the intermediate transfer belt unit. Transfer belt sensor (Intermediate transfer belt unit) 1. Clean the toner off of the sensor and its proximity using a blower. 2. Check the sensor actuator are correctly positioned. Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB.