Code: 8100
Description: DF eject release motor error When the DF eject release motor is driven, DF bundle discharge sensor does not turn on within 1 s.
Remedy: DF eject release motor DF bundle discharge unit sensor 1. Execute Motor - Eject Unlock (Full) of U240 finisher operation check. 2. Check that the eject guide of the process tray is opened and, if not, correct the guide. 3. Check that the drive from the motor reaches the eject guide. 4. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF bundle discharge unit sensor and DF main PWB (YC22) 5. If the wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the DF eject release motor.
DF bundle discharge unit sensor 1. Execute Finisher - Bundle Eject HP of U241 finisher switch check. 2. Check that the sensor and its mounting board are correctly positioned. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF bundle discharge unit sensor and DF main PWB (YC22) 4. Replace the DF bundle discharge unit sensor.
DF main PWB Replace the DF main PWB (Refer to the service manual for the document finisher).
DF bundle discharge unit sensor 1. Execute Finisher - Bundle Eject HP of U241 finisher switch check. 2. Check that the sensor and its mounting board are correctly positioned. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF bundle discharge unit sensor and DF main PWB (YC22) 4. Replace the DF bundle discharge unit sensor.
DF main PWB Replace the DF main PWB (Refer to the service manual for the document finisher).