Description: 4th drawer tray abnormality: The 4th drawer tray-up motor is not rotating or the 4th drawer tray is not moving normally. (the case that paper can be fed from any drawer except the 4th drawer)
Remedy: Does the tray go up? (Perform the output check: 03-248, 249) NO 1. Check if the connector of the tray-up motor is disconnected. 2. Check if the connector CN504 on the PFC board is disconnected. 3. Check if the connector pins are disconnected or the harnesses are open circuited. 4. Check if the conductor patterns on the PFC board is short circuited or open circuited. 5. Replace the tray-up motor. 6. Replace the PFC board. YES Is the tray-up sensor working? (Perform the input check: 03-[CopyON]/[9]/[F], /[9]/[E]) NO 1. Check if the connector of the sensor is disconnected. 2. Check if any of the connectors CN505 and CN506 on the PFC board is disconnected. 3. Check if the slit reaches the sensor. 4. Check if the connector pins are disconnected or the harnesses are open circuited. 5. Check if the conductor patterns on the PFC board is short circuited or open circuited. 6. Replace the tray-up sensor. 7. Replace the PFC board. YES 1. Check if the conductor pattern on the PFC board is short circuited or open circuited. 2. Replace the PFC board.