Description: Connection error between SLG board and SYS board
Remedy: (1) Check if the connector CN12 on the SLG board is completely inserted or not disconnected. (2) Check if the connector CN421 on the IMG board is completely inserted or not disconnected. (3) Check if the connector pin between the SLG board (connector CN12) and the IMG board (connector CN421) is disconnected, or the harness connecting these boards is short circuited or open circuited. (4) Check if the connector CN422 on the IMG board and the connector CN135 on the SYS board are completely inserted. (5) Check if the connector pin between the IMG board (connector CN422) and the SYS board (connector CN135) is disconnected. (6) Check if the conductor patterns on the SLG board, IMG board and SYS board are short circuited or open circuited. (7) Replace the SLG board if no problem is found in steps from (1) to (6) above. (8) If the problem is not corrected with the replacement of the SLG board, reinstall the removed SLG board and replace the IMG board. (9) If the problem is still not corrected with the replacement of the IMG board, reinstall the removed IMG board and replace the SYS board.