Description: SM multi feed sensor communication error (side multi tray) A communication error is detected 3 times in succession.
Remedy: Side multi tray Check the wiring connection status with the main unit and, if necessary, try connecting it again. SM main PWB 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. SM main PWB (YC1) and Engine PWB (YC19) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the SM main PWB (Refer to the service manual for the paper feeder). Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB.