Description: FGATE error 230-001: Y 230-002: M 230-003: C 230-004: K The BCU generates the FGATE signal based on the registration sensor ON timing. Then, it sends the signal to the LD units. The LD units send a feedback signal to the BCU. When the LD units start emitting laser beams, the feedback signal changes from High to Low. The SC code is generated when the BCU receives no feedback signal (stays High) from the LD unit 1 second after paper reaches the position where the laser should start writing.
Causes: • Poor connection between BCU and LD units • Defective BCU • Defective LD unit
Remedy: 1. Turn the main switch off and on. 2. Check the cables between the LD units and the BCU. 3. Replace the laser optics housing unit. 4. Replace the BCU.