Code: 3300
Description: Optical system (AGC) error
After AGC, correct input is not obtained at CCD.
After AGC, correct input is not obtained at CCD.
Causes: Defective connector cable or poor contact in the connector.
Defective exposure lamp
Defective CCD PWB.
Defective ISC PWB.
Defective main PWB.
Defective exposure lamp
Defective CCD PWB.
Defective ISC PWB.
Defective main PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. LED lamp PWB and ISC PWB (YC6) CCD PWB (YC2) and ISC PWB (YC9) ISC PWB (YC3) and main PWB (YC11)
Defective LED lamp PWB. Replace the LED lamp PWB and check for correct operation.
Defective ISC PWB. Replace the ISC PWB and check for correct operation.
Defective CCD PWB. Replace the ISU and check for correct operation.
Defective main PWB. Replace the main PWB and check for correct operation.
Defective LED lamp PWB. Replace the LED lamp PWB and check for correct operation.
Defective ISC PWB. Replace the ISC PWB and check for correct operation.
Defective CCD PWB. Replace the ISU and check for correct operation.
Defective main PWB. Replace the main PWB and check for correct operation.