Code: C0250
Description: Network scanner board* communication problem
• The response to the alive command to the network scanner transmitted once to 30 s does not come on the contrary three consecutive times or more.
• The response to the communication command transmitted to the network scanner does not return 75 s or more.
• The response to the alive command to the network scanner transmitted once to 30 s does not come on the contrary three consecutive times or more.
• The response to the communication command transmitted to the network scanner does not return 75 s or more.
Causes: Poor contact in the connector terminals.
Defective main PWB or network scanner board.
Defective main PWB or network scanner board.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC3 on the main PWB and the connector on the network scanner board, and the continuity across the connector terminals. Repair or replace if necessary.
Defective main PWB or network scanner board. Replace the main PWB or network scanner board and check for correct operation.
Defective main PWB or network scanner board. Replace the main PWB or network scanner board and check for correct operation.