Code: C0460
Description: Duplex unit communication problem
• A communication error from duplex section is detected 10 times in succession.
• A communication error from duplex section is detected 10 times in succession.
Causes: Poor contact in the connector terminals.
Defective engine PWB.
Defective duplex PWB.
Defective engine PWB.
Defective duplex PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC2 on the engine PWB and YC2 on the duplex PWB, and the continuity across the connector terminals. Repair or replace if necessary.
Defective engine PWB. Replace the engine PWB.
Defective duplex PWB. Replace the duplex PWB.
Defective engine PWB. Replace the engine PWB.
Defective duplex PWB. Replace the duplex PWB.