Mã lỗi C1040 — Kyocera TASKalfa 820

Code: C1040

Description: Lift motor 4 error
• When cassette 4 is inserted, lift limit switch 4 does not turn on within 33 s of lift motor 4 turning on. This error is detected four times successively.
• During copying, lift limit switch 4 does not turn on within 1 s of lift motor 4 turning on. This error is detected four times successively.
Causes: Broken gears or couplings of lift motor 4.
Defective lift motor 4.
Poor contact of lift motor 4 connector terminals.
Defective lift limit switch 4.
Poor contact of lift limit switch 4 connector terminals.
Defective casette PWB.
Remedy: Broken gears or couplings of lift motor 4. Replace lift motor 4.
Defective lift motor 4. Check for continuity across the coil. If none, replace lift motor 4.
Poor contact of lift motor 4 connector terminals. Reinsert the connector. Also check for continuity within the connector cable. If none, repair or replace the cable.
Defective lift limit switch 4. Run maintenance item U031 and turn lift limit switch 4 on and off manually. Replace lift limit switch 4 if indication of the corresponding sensor on the touch panel is not displayed in reverse.
Poor contact of lift limit switch 4 connector terminals. Reinsert the connector. Also check for continuity within the connector cable. If none, repair or replace the cable.
Defective casette PWB. Replace the casette PWB.