Code: C1150
Description: Side feeder lift motor going down error (optional side feeder)
• Lower limit detection switch does not turn off within 15 s of the side feeder lift motor starting (within 200 ms during paper feeding). This error is detected four times successively.
• Lower limit detection switch does not turn off within 15 s of the side feeder lift motor starting (within 200 ms during paper feeding). This error is detected four times successively.
Causes: Poor contact of lower limit detection switch connector terminals.
Defective side feeder main PWB.
Defective side feeder lift motor.
Defective side feeder main PWB.
Defective side feeder lift motor.
Remedy: Poor contact of lower limit detection switch connector terminals. Reinsert the connector. Also check for continuity within the connector cable. If none, repair or replace the cable.
Defective side feeder main PWB. Replace the side feeder main PWB.
Defective side feeder lift motor. Run maintenance mode U247 and measure the voltage between terminals YC5-A12 (side-feeder main circuit board) and YC6- B11. (Make sure all of LUSSW, UCSSW, LLSSW and RCSSW are off.) Despite either DC24V or DC-24V is observed but if the side-feeder lift motor does not operate, replace the side-feeder lift motor.
Defective side feeder main PWB. Replace the side feeder main PWB.
Defective side feeder lift motor. Run maintenance mode U247 and measure the voltage between terminals YC5-A12 (side-feeder main circuit board) and YC6- B11. (Make sure all of LUSSW, UCSSW, LLSSW and RCSSW are off.) Despite either DC24V or DC-24V is observed but if the side-feeder lift motor does not operate, replace the side-feeder lift motor.