Code: C3200
Description: Exposure lamp problem
• Check the CCD input value for the lighting status of the exposure lamp 500 ms after the exposure lamp is lit and the carriage is moved to the shading position. If the exposure lamp does not light, a further 100 ms later, check the CCD input. The exposure lamp does not light after 50 retries.
• Check the CCD input value for the lighting status of the exposure lamp 500 ms after the exposure lamp is lit and the carriage is moved to the shading position. If the exposure lamp does not light, a further 100 ms later, check the CCD input. The exposure lamp does not light after 50 retries.
Causes: Defective scanner PWB.
Defective exposure lamp or inverter PWB.
Incorrect shading position.
Poor contact of the connector terminals.
Defective CCD PWB.
Defective exposure lamp or inverter PWB.
Incorrect shading position.
Poor contact of the connector terminals.
Defective CCD PWB.
Remedy: Defective scanner PWB. Replace the scanner PWB and check for correct operation.
Defective exposure lamp or inverter PWB. Replace the exposure lamp or inverter PWB.
Incorrect shading position. Adjust the position of the contact glass (shading plate). If the problem still occurs, replace the scanner home position switch.
Poor contact of the connector terminals. Check the connection of connectors YC3, YC4 and YC5 on the scanner PWB, YC5, YC6 and YC8 on the SHD PWB and YC1, YC2 and YC3 on the CCD PWB, and the continuity across the connector terminals. Repair or replace if necessary.
Defective CCD PWB. Replace the CCD PWB and check for correct operation.
Defective exposure lamp or inverter PWB. Replace the exposure lamp or inverter PWB.
Incorrect shading position. Adjust the position of the contact glass (shading plate). If the problem still occurs, replace the scanner home position switch.
Poor contact of the connector terminals. Check the connection of connectors YC3, YC4 and YC5 on the scanner PWB, YC5, YC6 and YC8 on the SHD PWB and YC1, YC2 and YC3 on the CCD PWB, and the continuity across the connector terminals. Repair or replace if necessary.
Defective CCD PWB. Replace the CCD PWB and check for correct operation.