Code: C5500
Description: Drum surface potential sensor problem 1
• The sensor output is 0.5 V or less when MC REM signal is turned on.
• The sensor output is 0.5 V or less when MC REM signal is turned on.
Causes: Poor contact in the drum surface potential sensor connector terminals.
Defective drum surface potential sensor.
Defective high voltage PWB.
Defective engine PWB.
Defective drum surface potential sensor.
Defective high voltage PWB.
Defective engine PWB.
Remedy: Poor contact in the drum surface potential sensor connector terminals. Check the connection of connector YC5 on the engine PWB. Reinsert the connector. Also check for continuity within the connector cable. If none, repair or replace the cable.
Defective drum surface potential sensor. Replace the drum surface potential sensor.
Defective high voltage PWB. Replace the high voltage PWB and check for correct operation.
Defective engine PWB. Replace the engine PWB and check for correct operation.
Defective drum surface potential sensor. Replace the drum surface potential sensor.
Defective high voltage PWB. Replace the high voltage PWB and check for correct operation.
Defective engine PWB. Replace the engine PWB and check for correct operation.