Code: C7300
Description: Toner hopper problem
• During toner replenishment after toner empty has been detected, toner empty could not be cleared in 3 times of 360 s.
• During toner replenishment after toner empty has been detected, toner empty could not be cleared in 3 times of 360 s.
Causes: Defective toner level detection sensor.
Poor contact in the toner level detection sensor connector terminals.
Poor contact in the toner level detection sensor connector terminals.
Remedy: Defective toner level detection sensor. Replace the toner level detection sensor.
Poor contact in the toner level detection sensor connector terminals. Check the connection of connectors YC2 and YC5 on the deck PWB and YC3 on the engine PWB. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.
Poor contact in the toner level detection sensor connector terminals. Check the connection of connectors YC2 and YC5 on the deck PWB and YC3 on the engine PWB. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.