Code: 0094
Description: 2nd image transfer pressure / retraction failure
• The 2nd image transfer retraction position sensor is not activated (retracted position) within a given period of time after the retraction sequence of the 2nd transfer roller has been started. • The 2nd image transfer retraction position sensor is not deactivated (pressed position) within a given period of time after the pressure sequence of the 2nd transfer roller has been started.
• The 2nd image transfer retraction position sensor is not activated (retracted position) within a given period of time after the retraction sequence of the 2nd transfer roller has been started. • The 2nd image transfer retraction position sensor is not deactivated (pressed position) within a given period of time after the pressure sequence of the 2nd transfer roller has been started.
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check the SD4 connector for proper connection and correct as necessary. 3 Check M1 for proper drive coupling and correct as necessary. 4 Check SD4 for proper drive coupling and correct as necessary. 5 Check the PRCB connector for proper connection and correct as necessary. 6 PS3 sensor check PRCB PJ12-3 (ON) C-2. 7 SD4 operation check PRCB PJ10-6 (REM) C-9. 8 M1 operation check PRCB PJ8-1 to 6 C-2. 9 Change M1. 10 Change SD4. 11 Change PRCB.