Mã lỗi 17H — Konica-Minolta Magicolor 2430DL

Code: 17H

Description: Rack rotation failure
• The Rack Positioning Sensor is in the blocked state when the Rack Motor remains deenergized. • The Rack Positioning Sensor is not blocked a second time even after the lapse of a predetermined period of time after it has been blocked once while the Rack Motor remains energized. • The Rack Positioning Sensor is unable to detect the• The count value of the edge of ON signal of the Rack Positioning Sensor during each developing positions are not a predetermined value while the Rack Motor is turning. deceleration control position after the lapse of a given period of time after the Rack Motor has started while the Rack Motor is turning.
Remedy: 1 Check the M2 connector for proper connection and correct as necessary. 2 Check M2 for proper drive coupling and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 PC3 sensor check. PWB-A PJ5A-11 (ON) 4-C 5 M2 operation check. PWB-A PJ5A-1-4 (Pulse Output) 4-B. 6 Change PWB-A.