Code: 15H
Description: Cleaning Blade pressure /retraction failure
• The state of the Retraction Position Sensor/Cleaning Blade is not changed from the blocked to unblocked state even after the lapse of a predetermined period of time during predrive. • The Retraction Position Sensor/Cleaning Blade is in the blocked state even after the lapse of a predetermined period of time during predrive. • The Retraction Position Sensor/Cleaning Blade is not unblocked (blade in the retracted position) within a predetermined period of time after the retraction sequence of the Cleaning Blade has been started. • The Retraction Position Sensor/Cleaning Blade is not blocked (blade in the pressed position) within a predetermined period of time after the pressure sequence of the Cleaning Blade has been started.
• The state of the Retraction Position Sensor/Cleaning Blade is not changed from the blocked to unblocked state even after the lapse of a predetermined period of time during predrive. • The Retraction Position Sensor/Cleaning Blade is in the blocked state even after the lapse of a predetermined period of time during predrive. • The Retraction Position Sensor/Cleaning Blade is not unblocked (blade in the retracted position) within a predetermined period of time after the retraction sequence of the Cleaning Blade has been started. • The Retraction Position Sensor/Cleaning Blade is not blocked (blade in the pressed position) within a predetermined period of time after the pressure sequence of the Cleaning Blade has been started.
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the SL3 connector for proper connection and correct as necessary. 4 Check the PWB-A connector for proper connection and correct as necessary. 5 PC6 sensor check. PWB-A PJ9A-11 (ON) 2-F 6 SL3 operation check. PWB-A PJ10-5 (REM) 2-F 7 M1 operation check. PWB-A PJ8A-5 (REM) PWB-A PJ8A-8 (LOCK) 2-G-H 8 Change PWB-A.