Code: 0C
Description: Power supply cooling fan motor malfunction
• The fan motor lock signal remains HIGH for a predetermined consecutive period of time while the power supply cooling fan motor remains energized.
• The fan motor lock signal remains HIGH for a predetermined consecutive period of time while the power supply cooling fan motor remains energized.
Remedy: 1 Check the FM1 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 FM1 operation check. 2500W: PRCB PJ4PRCB-1 (REM) PRCB PJ4PRCBB-3 (LOCK) 2530 DL: PRCB PJ4PRCB-1 (REM) PRCB PJ4PRCB-3 (LOCK) 2550/2550DN: PRCB PJ4PRCB-1 (REM) PRCB PJ4PRCB-3 (LOCK) 2500W: C-5 2530 DL: C-4 2550/2550DN: C-4. 5 Change PRCB. 6 Change DCPU.